Doublet- and economic parameters HT-ATES

The two tables below show the technical and economic parameters used in the calculations. The Calculation model (HT-ATES) page contains a more detailed description of these parameters and the depth-dependent parameters.

Technical parameters HT-ATES doublet:

Technical parametersValueUnit
aquifer top depthfrom mapm
aquifer thicknessfrom mapm
aquifer net-to-grossfrom map-
aquifer permeabilityfrom mapmDarcy
aquifer temperaturefrom 3D model°C
aquifer water salinitydepth-dependentppm
aquifer anisotropy8-
injection temperature hot well80°C
cut-off temperature (minimal production temperature in hot well)45°C
injection temperature cold well (retour temperature heating network)40°C
injection/production period (max. 182 days)*120day
ROSIM simulation time (constant capacity after x years)15year
minimum depth**100m
maximum depth**800m
filter fraction (% from aquifer thickness)1-
specific clogging verlocity (Vv)0.3m/year
Membrane Filter Index (MFI)0.1s/l2
depth factor0.00632 (depth factor from 158 m)-
distance between two wells at reservoir level2x thermal radiusm
outer diameter (open production interval)31inch
pump depth150m
put segment length30m

 

* when the number of production days is <20, the simulation stops

** for faster calculation

 

Economic parameters doublet:

Economic parametersValueUnit
economic lifetime30year
drilling time1year
well costsdepth-dependentM€
CAPEX base costs (excl. wells)1.1M€
CAPEX variable costs (excl. wells)25€/kW
CAPEX contingency25%
annual OPEX base costs70000
annual OPEX per unit power6.8€/kW
annual OPEX per unit produced energy0€ct/kWh
electricity purchase price for operations8€ct/kWh
tax rate25%
interest on loan5%
inflation2%
required return on equity7%
debt ratio80%